Exfo CableSHARK P3 VF/DSL Cable Qualifier Instrukcja Użytkownika Strona 205

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 321
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 204
CableSHARK P3 User Guide
193
If the pair does not have a fault on it, the CableSHARK will display the following message:
CONGRATULATIONS
!
FIGURE 12.1.1.5A NO FAULT DETECTED
If there is a small voltage on the line and there is a resistive fault, this is likely a battery cross situation. The
RFL test will indicate the following:
Yel low Blue Green
MAIN
MENU
E
CHG
WARNING
Connect a good pair to Yellow and Blue.
Connect far end strap from wire connected to Black
to both ends of good pair.
!
F
Black Red Green
CABLE
TESTS
Battery Cross fault detected on TIP, 5.9 Mohms, CO Voltage -48.0V
Battery Cross fault detected on TIP, 5.9 Mohms
Yel low Blue Green
FIGURE 12.1.1.5C RFL MESSAGE INDICATING PLACEMENT OF STRAP
Connect the strap (see Section 12.1.1.6) as indicated and press the CONTINUE button.
Przeglądanie stron 204
1 2 ... 200 201 202 203 204 205 206 207 208 209 210 ... 320 321

Komentarze do niniejszej Instrukcji

Brak uwag