Ethernet and Fibre Channel Application 501
Frame Format Configuration
Frame Format Configuration
This pop-up window is only available with EtherSAM (Y.1564) test case.
Frame Format
OUI is available when the Data Link is set to 802.3 SNAP and allows the
selection of the Organizationally Unique Identifier (OUI). Choices are
RFC1042, 802.1H, and User Defined (when Network is set to None).
When User Defined is selected, enter the OUI hexadecimal value
(000000 to FFFFFF).
EtherType is available when Network is set to None and allows to
enter the EtherType hexadecimal value (0000 to FFFF).