Exfo RTU 310-310G IP Services Test Head Instrukcja Użytkownika Strona 149

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 148
Port Tabs
Ethernet and Fibre Channel Application 137
Electrical RX
Frequency Analysis
Note: Frequency Analysis is not available for 10Base-T test.
Frequency (bps): Indicates the frequency of the input signal.
Frequency Offset: Indicates the offset between the standard rate
specification and the rate of the input signal.
Max. Positive Offset: Indicates the offset between the standard rate
specification and the largest rate recorded from the received signal.
Max. Negative Offset: Indicates the offset between the standard rate
specification and the smallest rate recorded from the received signal.
Offset Unit: Allows the selection of the frequency offset unit. Choices are
bps and ppm. The default setting is ppm.
Przeglądanie stron 148
1 2 ... 144 145 146 147 148 149 150 151 152 153 154 ... 546 547

Komentarze do niniejszej Instrukcji

Brak uwag