Exfo RTU 310-310G IP Services Test Head Instrukcja Użytkownika Strona 171

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 170
Port Tabs
Ethernet and Fibre Channel Application 159
Advanced Auto-Neg. RX
Advanced Auto-Neg. RX
Note: Advanced auto-negotiation is not available with the optical 100 Mbps and
10 Gig-E interfaces.
Click TEST, Port1/2, and Advanced Auto-Neg RX.
Status
Link: A green Link LED indicates that there is a link at the input port of
the corresponding Ethernet interface. A red LED indicates that there is
no link at the input port of the corresponding Ethernet interface.
Auto-Negotiation: Indicates the auto-negotiation status. Possible
values are:
Negotiating: indicates that the auto-negotiation process is running and
not completed yet.
Completed: indicates that the auto-negotiation process has completed
successfully.
Parallel Detect Fail: indicates that auto-negotiation has failed through
the parallel detection process while negotiating in 10/100Base-T.
Remote Fault: Indicates the remote fault error. Possible values are
Error-Offline (1000Base-X only) , Error-Link Fault (1000Base-X only),
and Error-Auto-Negotiation error.
Speed: Indicates the negotiated speed. Possible values are 10, 100,
and 1000.
Przeglądanie stron 170
1 2 ... 166 167 168 169 170 171 172 173 174 175 176 ... 546 547

Komentarze do niniejszej Instrukcji

Brak uwag