Operating Your RTU in OTDR Measuring Mode
Fiber Guardian 189
Managing Cable Templates
Adding Cable Templates
For each template, you have to specify the following items:
Tolerance between events, in meters (for fibers to be considered as
identical).
Optical routes on which the tests will be performed.
Parameters related to the test setup (see Managing Test Setups on
page 146).
You can specify only one wavelength per template.
The provided values correspond to the default values associated
with the proactive maintenance test setup (see Defining Default
Values for Test Setups on page 133).
Parameters related to the test program (see Managing Test Programs
on page 155).
If you modify the acquisition or analysis parameters, the application will
prompt you to perform a reference. For more information, see Creating the
Reference Traces on page 160.