Exfo IQS-2600B Tunable Laser Source for IQS Platforms Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Exfo IQS-2600B Tunable Laser Source for IQS Platforms. EXFO IQS-2600B Tunable Laser Source for IQS Platforms User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - IQS-2600B

User GuideTunable Laser Source for IQS PlatformsIQS-2600B

Strona 2

Introducing the IQS-2600B Tunable Laser Source4 IQS-2600BConventionsConventionsBefore using the product described in this manual, you should understan

Strona 3 - Contents

SCPI Command Reference94 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:CYCLe?Description This query returns the number

Strona 4

SCPI Command ReferenceTunable Laser Source 95Product-Specific Commands—DescriptionResponse(s) Cycle: The response data syntax for <Cycle> is def

Strona 5

SCPI Command Reference96 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:DIRectionDescription This command controls the d

Strona 6 - DECLARATION OF CONFORMITY

SCPI Command ReferenceTunable Laser Source 97Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:DIRection?Description This query retu

Strona 7 - 1 Introducing the IQS-2600B

SCPI Command Reference98 IQS-2600BProduct-Specific Commands—DescriptionONEWAY, the sweep is performed in one direction, from start to stop.TWOWAY, the

Strona 8 - Typical Applications

SCPI Command ReferenceTunable Laser Source 99Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:REPeatDescription This command is use

Strona 9 - Tunable Laser Source 3

SCPI Command Reference100 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:REPeat?Description This query returns the sweep

Strona 10 - IMPORTANT

SCPI Command ReferenceTunable Laser Source 101Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STARtDescription This command allows

Strona 11 - 2 Safety Information

SCPI Command Reference102 IQS-2600BProduct-Specific Commands—DescriptionDEFault allows the instrument to select a value for the <StartWavelength>

Strona 12

SCPI Command ReferenceTunable Laser Source 103Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STARt?Description This query returns

Strona 13 - Tunable Laser Source

Tunable Laser Source 52 Safety InformationWhile handling optical fibers, laser radiation may be encountered at source output ports and fiber ends. Avo

Strona 14 - 8 IQS-2600B

SCPI Command Reference104 IQS-2600BProduct-Specific Commands—DescriptionResponse(s) StartWavelength: The response data syntax for <StartWavelength&

Strona 15 - Retaining screw knob

SCPI Command ReferenceTunable Laser Source 105Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STOPDescription This command allows

Strona 16 - 10 IQS-2600B

SCPI Command Reference106 IQS-2600BProduct-Specific Commands—DescriptionExample(s) SOUR:WAV:SWE:STOP 0.00000155 (if current unit is meter)SOUR:WAV:SWE

Strona 17 - (white background)

SCPI Command ReferenceTunable Laser Source 107Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STOP?Description This query returns

Strona 18 - 12 IQS-2600B

SCPI Command Reference108 IQS-2600BProduct-Specific Commands—DescriptionResponse(s) StopWavelength: The response data syntax for <StopWavelength>

Strona 19 - Status Bar

SCPI Command ReferenceTunable Laser Source 109Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:SPEedDescription This command allows

Strona 20 - 14 IQS-2600B

SCPI Command Reference110 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:SPEed?Description This query returns the sweep

Strona 21 - Exiting the Application

SCPI Command ReferenceTunable Laser Source 111Product-Specific Commands—DescriptionResponse(s) Speed: The response data syntax for <Speed> is de

Strona 22

SCPI Command Reference112 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STATeDescription This function starts or stops

Strona 23 - 4 Setting Standard Parameters

SCPI Command ReferenceTunable Laser Source 113Product-Specific Commands—DescriptionExample(s) UNIT:SPEC MSOUR:WAV:SWE:REP CONTSOUR:WAV:SWE:STAR 0.0000

Strona 25 - Selecting the Display Unit

SCPI Command Reference114 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STATe?Description This query returns a value in

Strona 26 - Selecting a Wavelength

SCPI Command ReferenceTunable Laser Source 115Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:TIME?Description This query returns

Strona 27

SCPI Command Reference116 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STEP[:WIDTh]Description This command allows you

Strona 28 - Setting the Power

SCPI Command ReferenceTunable Laser Source 117Product-Specific Commands—DescriptionExample(s) SOUR:WAV:SWE:STEP 0.00000001SOUR:WAV:SWE:STEP 1.6NMNotes

Strona 29 - Using the Slider

SCPI Command Reference118 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STEP[:WIDTh]?Description This query returns the

Strona 30 - Adding Items to Lists

SCPI Command ReferenceTunable Laser Source 119Product-Specific Commands—DescriptionResponse(s) StepWidth: The response data syntax for <StepWidth&g

Strona 31 - Deleting Items from Lists

SCPI Command Reference120 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:DWELlDescription This command allows you to set

Strona 32 - 26 IQS-2600B

SCPI Command ReferenceTunable Laser Source 121Product-Specific Commands—DescriptionExample(s) SOUR:WAV:SWE:DWEL 550MSNotes This function cannot be per

Strona 33

SCPI Command Reference122 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:DWELl?Description This query returns the time i

Strona 34

SCPI Command ReferenceTunable Laser Source 123Product-Specific Commands—DescriptionResponse(s) DwellTime: The response data syntax for <DwellTime&g

Strona 35 - 5 Setting Sweep Parameters

Tunable Laser Source 73 Getting Started with Your Tunable Laser SourceInserting and Removing Test ModulesTo insert a module into the controller or exp

Strona 36 - Selecting the Sweep Mode

SCPI Command Reference124 IQS-2600BProduct-Specific Commands—Description:TRIGger[1..n][:SEQuence]:INPutDescription This command allows you to set the

Strona 37 - Using the Stepped Mode

SCPI Command ReferenceTunable Laser Source 125Product-Specific Commands—Description:TRIGger[1..n][:SEQuence]:INPut?Description This query returns the

Strona 38 - 32 IQS-2600B

SCPI Command Reference126 IQS-2600BProduct-Specific Commands—Description:UNIT[1..n]:SPECtrumDescription This command allows you to set the spectrum un

Strona 39 - Setting the Cycle Options

SCPI Command ReferenceTunable Laser Source 127Product-Specific Commands—Description:UNIT[1..n]:SPECtrum?Description This query returns the current spe

Strona 41

Tunable Laser Source 129C Trigger Option TheoryYour Tunable Laser Source features Trigger In and Out connectors. When the trigger option is set to On,

Strona 42 - 36 IQS-2600B

Trigger Option Theory130 IQS-2600BTrigger Option in Stepped ModeTrigger Option in Stepped ModeThe sweep will begin when you press on Start. The system

Strona 43

IndexTunable Laser Source 131IndexAAbout function tab ... 58adding items on the current lists... 24adj

Strona 44

Index132 IQS-2600BIidentification label ... 57identification, slot ... 13increm

Strona 45 - Starting a Sweep

IndexTunable Laser Source 133selectingdisplay unit... 19from a stored list ...

Strona 46

Getting Started with Your Tunable Laser Source8 IQS-2600BInserting and Removing Test Modules4. Insert the protruding edges of the module into the groo

Strona 47 - Laser Source

NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT

Strona 48 - Using Monitor Windows

MARKING REQUIREMENTS㪖㽷尐㻑Productℶ❐Environmental protection use period (years)䘾⬒≬㔳∎䞷㦮棟 ( ㄃ )Logo㪖㉦This Exfo product㦻 EXFO ℶ❐10Batterya䟄㻯aa. If applicabl

Strona 49

www.EXFO.com · [email protected]/N: 1062026CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-

Strona 50 - Using QuickTools

Getting Started with Your Tunable Laser SourceTunable Laser Source 9Inserting and Removing Test ModulesThe module is correctly inserted when its front

Strona 51

Getting Started with Your Tunable Laser Source10 IQS-2600BInserting and Removing Test Modules3. Cover empty slots with the supplied protective covers.

Strona 52

Getting Started with Your Tunable Laser SourceTunable Laser Source 11Starting the Tunable Laser Source ApplicationStarting the Tunable Laser Source Ap

Strona 53 - 8 Maintenance

Getting Started with Your Tunable Laser Source12 IQS-2600BStarting the Tunable Laser Source ApplicationNote: Pressing the LED push button will not act

Strona 54

Getting Started with Your Tunable Laser SourceTunable Laser Source 13Starting the Tunable Laser Source ApplicationTitle BarThe title bar is located at

Strona 55

ii IQS-2600BCopyright © 2003–2011 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transm

Strona 56

Getting Started with Your Tunable Laser Source14 IQS-2600BEntering Values Using Sliders and Numeric BoxesEntering Values Using Sliders and Numeric Box

Strona 57

Getting Started with Your Tunable Laser SourceTunable Laser Source 15Exiting the ApplicationExiting the ApplicationClosing any application that is not

Strona 59

Tunable Laser Source 174 Setting Standard ParametersThe standard parameters are set through the Instrument function tab.

Strona 60 - Recycling and Disposal

Setting Standard Parameters18 IQS-2600BSwitching between Normal and High-Resolution (HR) ModesSwitching between Normal and High-Resolution (HR) ModesY

Strona 61 - 9 Troubleshooting

Setting Standard ParametersTunable Laser Source 19Selecting the Display UnitSelecting the Display UnitIt is possible to select the display unit with w

Strona 62 - Viewing Online Documentation

Setting Standard Parameters20 IQS-2600BSelecting a WavelengthSelecting a WavelengthThere are several ways to select a wavelength for testing.Whenever

Strona 63 - IQS-2600B-XX-XX

Setting Standard ParametersTunable Laser Source 21Selecting a WavelengthRetrieving a Wavelength from a Stored ListTo select a wavelength from the list

Strona 64 - 58 IQS-2600B

Setting Standard Parameters22 IQS-2600BSetting the PowerSetting the PowerThere are several ways to select a power value for testing.Whenever you use c

Strona 65 - Transportation

Setting Standard ParametersTunable Laser Source 23Setting the PowerRetrieving Power Step Value from a Stored ListTo select a power step value from the

Strona 66

ContentsTunable Laser Source iiiContentsCertification Information ...

Strona 67 - 10 Warranty

Setting Standard Parameters24 IQS-2600BAdding Items to ListsAdding Items to ListsYou can add items to the current Wavelength Presets, Wavelength Step,

Strona 68 - Certification

Setting Standard ParametersTunable Laser Source 25Deleting Items from ListsDeleting Items from ListsYou can delete items from the current Wavelength P

Strona 69 - Service and Repairs

Setting Standard Parameters26 IQS-2600BSaving and Recalling ConfigurationsSaving and Recalling ConfigurationsOnce you have set the IQS-2600B Tunable L

Strona 70 - 64 IQS-2600B

Setting Standard ParametersTunable Laser Source 27Saving and Recalling ConfigurationsTo recall a configuration:1. Select the Configuration function ta

Strona 72 - GENERAL SPECIFICATIONS

Tunable Laser Source 295 Setting Sweep ParametersYour Tunable Laser Source allows you to perform automatic wavelength scans according to user-defined

Strona 73 - Technical Specifications

Setting Sweep Parameters30 IQS-2600BSetting a Delay for the SweepSetting a Delay for the SweepA delay at the beginning of a sweep can allow you to coo

Strona 74

Setting Sweep ParametersTunable Laser Source 31Selecting the Sweep ModeUsing the Stepped ModeTo select the Stepped sweep mode, click the appropriate b

Strona 75 - B SCPI Command Reference

Setting Sweep Parameters32 IQS-2600BSelecting the Incoming Trigger OptionSelecting the Incoming Trigger OptionThe incoming trigger option allows you t

Strona 76 - Quick Reference Command Tree

Setting Sweep ParametersTunable Laser Source 33Setting the Cycle OptionsSetting the Cycle OptionsThe cycle options allow you to specify settings in bo

Strona 77

Contentsiv IQS-2600B7 Monitoring Your Tunable Laser Source ...41Using Monitor Windows ...

Strona 78 - :ABORt[1..n]

Setting Sweep Parameters34 IQS-2600BSetting the Sweep DirectionSetting the Sweep DirectionThe sweep can be either unidirectional, meaning that it will

Strona 79 - :CALibration[1..n]:WAVelength

Tunable Laser Source 356 Operating your Tunable Laser SourceCleaning and Connecting Optical FibersTo connect the fiber-optic cable to the port:1. Insp

Strona 80

Operating your Tunable Laser Source36 IQS-2600BCleaning and Connecting Optical Fibers3. Carefully align the connector and port to prevent the fiber en

Strona 81 - :INITiate[1..n][:IMMediate]

Operating your Tunable Laser SourceTunable Laser Source 37Installing the EXFO Universal Interface (EUI)Installing the EXFO Universal Interface (EUI)Th

Strona 82 - 76 IQS-2600B

Operating your Tunable Laser Source38 IQS-2600BActivating/Deactivating Light EmissionActivating/Deactivating Light EmissionBefore turning on the Tunab

Strona 83 - Tunable Laser Source 77

Operating your Tunable Laser SourceTunable Laser Source 39Starting a SweepStarting a SweepAfter setting your sweep parameters as explained in Setting

Strona 85

Tunable Laser Source 417 Monitoring Your Tunable Laser SourceWhen using your IQS-2600B Tunable Laser Source module, either alone or with other modules

Strona 86 - [:IMMediate][:AMPLitude]?

Monitoring Your Tunable Laser Source42 IQS-2600BUsing Monitor WindowsTo select modules and display their monitor windows:1. On the Current Modules fun

Strona 87

Monitoring Your Tunable Laser SourceTunable Laser Source 43Using Monitor WindowsClosemonitorwindowRearrangemonitorsin columnsRepositionmonitor windows

Strona 88 - :SOURce[1..n]:POWer:STATe

Certification InformationTunable Laser Source vCertification InformationFCC InformationElectronic test equipment is exempt from Part 15 compliance (FC

Strona 89 - :SOURce[1..n]:POWer:STATe?

Monitoring Your Tunable Laser Source44 IQS-2600BUsing QuickToolsUsing QuickToolsWith QuickTools, you can fine-tune your module directly, while keeping

Strona 90 - :SOURce[1..n]:WAVelength[:CW]

Monitoring Your Tunable Laser SourceTunable Laser Source 45Using QuickToolsTo c lo se Qui ck Tool s:Click the Close button located at the top of the

Strona 92 - 86 IQS-2600B

Tunable Laser Source 478 MaintenanceTo help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them and clean th

Strona 93 - Example(s) SOUR:WAV?

Maintenance48 IQS-2600BCleaning Fixed ConnectorsCleaning Fixed ConnectorsRegular cleaning of connectors will help maintain optimum performance. Do not

Strona 94 - :SOURce[1..n]:WAVelength:MODE

MaintenanceTunable Laser Source 49Cleaning Fixed Connectors7. Slowly insert the cleaning tip into the connector until it reaches the ferrule inside (a

Strona 95 - Tunable Laser Source 89

Maintenance50 IQS-2600BCleaning EUI ConnectorsCleaning EUI ConnectorsRegular cleaning of EUI connectors will help maintain optimum performance. There

Strona 96 - 90 IQS-2600B

MaintenanceTunable Laser Source 51Cleaning EUI Connectors5. Repeat steps 3 to 4 with a dry cleaning tip.Note: Make sure you don’t touch the soft end o

Strona 97 - Tunable Laser Source 91

Maintenance52 IQS-2600BAdjusting Your Unit According to WavelengthAdjusting Your Unit According to WavelengthIt is possible to introduce an offset in

Strona 98 - 92 IQS-2600B

MaintenanceTunable Laser Source 53Adjusting Your Unit According to WavelengthThe difference between the pre-selected wavelength and the measured wavel

Strona 99 - Tunable Laser Source 93

Certification Informationvi IQS-2600BPage 1 of 1 DECLARATION OF CONFORMITY Application of Council Directive(s): 2006/95/EC ± The Low Voltage Direc

Strona 100 - 94 IQS-2600B

Maintenance54 IQS-2600BRecalibrating the UnitRecalibrating the UnitManufacturing and service center calibrations are based on the ISO/IEC 17025 Standa

Strona 101 - Tunable Laser Source 95

Tunable Laser Source 559 TroubleshootingSolving Common ProblemsIf you encounter one of the problems listed below, try to solve it first with the given

Strona 102 - DIRection

Troubleshooting56 IQS-2600BViewing Online DocumentationViewing Online DocumentationAn online version of the IQS-2600B Tunable Laser Source user guide

Strona 103 - DIRection?

TroubleshootingTunable Laser Source 57Contacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or tec

Strona 104

Troubleshooting58 IQS-2600BContacting the Technical Support GroupYou may also be requested to provide software and module version numbers.This informa

Strona 105 - Tunable Laser Source 99

TroubleshootingTunable Laser Source 59TransportationTransportationMaintain a temperature range within specifications when transporting the unit. Trans

Strona 107 - Tunable Laser Source 101

Tunable Laser Source 6110 WarrantyGeneral InformationEXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship for a period

Strona 108 - 102 IQS-2600B

Warranty62 IQS-2600BExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of any of its products at any time witho

Strona 109 - Tunable Laser Source 103

WarrantyTunable Laser Source 63Service and RepairsService and RepairsEXFO commits to providing product service and repair for five years following the

Strona 110 - 104 IQS-2600B

Tunable Laser Source 11 Introducing the IQS-2600B Tunable Laser SourceGeneral InformationThe IQS-2600B Tunable Laser Source addresses the testing requ

Strona 111 - Tunable Laser Source 105

Warranty64 IQS-2600BEXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact your nearest authorized se

Strona 112 - 106 IQS-2600B

Tunable Laser Source 65A Technical SpecificationsIMPORTANTThe following technical specifications can change without notice. The information presented

Strona 113 - Tunable Laser Source 107

Technical Specifications66 IQS-2600BGENERAL SPECIFICATIONSOutput fiber type SMF-28Operating temperature 10 °C to 40 °C (50 °F to 104 °F)Storag

Strona 114 - 108 IQS-2600B

Technical SpecificationsTunable Laser Source 67WAVELENGTHRange (nm) 1510 to 1612Display resolution (pm) 1Effective spectral linewidth FWHMb (GHz) 1

Strona 115 - Tunable Laser Source 109

Technical Specifications68 IQS-2600BGENERAL SPECIFICATIONSOutput fiber type SMF-28Operating temperature 10 °C to 40 °C (50 °F to 104 °F)Storag

Strona 116 - 110 IQS-2600B

Tunable Laser Source 69B SCPI Command ReferenceThis appendix presents detailed information on the commands and queries supplied with your IQS-2600B Tu

Strona 117 - Tunable Laser Source 111

SCPI Command Reference70 IQS-2600BQuick Reference Command TreeQuick Reference Command TreeCommand Parameter(s) P.ABORt[1..n] 72CALibration[1..n]WAVele

Strona 118 - 112 IQS-2600B

SCPI Command ReferenceTunable Laser Source 71Quick Reference Command TreeREPeat CONTinuous|NCONtinuous 99REPeat? 100STARt <StartWavelength[<wsp&

Strona 119 - Tunable Laser Source 113

SCPI Command Reference72 IQS-2600BProduct-Specific Commands—DescriptionProduct-Specific Commands—Description:ABORt[1..n]Description This command is us

Strona 120 - 114 IQS-2600B

SCPI Command ReferenceTunable Laser Source 73Product-Specific Commands—Description:CALibration[1..n]:WAVelengthDescription This command introduces an

Strona 121 - Tunable Laser Source 115

Introducing the IQS-2600B Tunable Laser Source2 IQS-2600BTypical Appl ication sThe IQS-2600B Tunable Laser Source supports local control (via the IQS

Strona 122 - STEP[:WIDTh]

SCPI Command Reference74 IQS-2600BProduct-Specific Commands—DescriptionExample(s) SOUR:POW:STATE ON- Wait for the power on operation to be complete.SO

Strona 123

SCPI Command ReferenceTunable Laser Source 75Product-Specific Commands—Description:INITiate[1..n][:IMMediate]Description This function starts the swee

Strona 124 - STEP[:WIDTh]?

SCPI Command Reference76 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:POWer:ALC[:STATe]Description This command activates the laser out

Strona 125

SCPI Command ReferenceTunable Laser Source 77Product-Specific Commands—Description:SOURce[1..n]:POWer:ALC[:STATe]?Description This query returns state

Strona 126 - 120 IQS-2600B

SCPI Command Reference78 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:POWer[:LEVel][:IMMediate][:AMPLitude]Description This command set

Strona 127 - SCPI Command Reference

SCPI Command ReferenceTunable Laser Source 79Product-Specific Commands—DescriptionExample(s) SOUR:POW:LEV:IMM:AMPL -6.35SOUR:POW -1.25Notes This funct

Strona 128 - 122 IQS-2600B

SCPI Command Reference80 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:POWer[:LEVel][:IMMediate][:AMPLitude]?Description This query retu

Strona 129 - Tunable Laser Source 123

SCPI Command ReferenceTunable Laser Source 81Product-Specific Commands—DescriptionResponse(s) OutputPower: The response data syntax for <OutputPowe

Strona 130 - 124 IQS-2600B

SCPI Command Reference82 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:POWer:STATeDescription This command turns the optical source on o

Strona 131 - Tunable Laser Source 125

SCPI Command ReferenceTunable Laser Source 83Product-Specific Commands—Description:SOURce[1..n]:POWer:STATe?Description This query returns a value ind

Strona 132 - :UNIT[1..n]:SPECtrum

Introducing the IQS-2600B Tunable Laser SourceTunable Laser Source 3IQS-2600CT Tunable Laser Source for IQS-12004B DWDM Passive Component Test SystemI

Strona 133 - :UNIT[1..n]:SPECtrum?

SCPI Command Reference84 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength[:CW]Description This command selects the source's

Strona 134

SCPI Command ReferenceTunable Laser Source 85Product-Specific Commands—DescriptionExample(s) SOUR:WAV 0.00000155SOUR:WAV 1550NMSOUR:WAV MAXNotes This

Strona 135 - C Trigger Option Theory

SCPI Command Reference86 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength[:CW]?Description This query returns the output wavelen

Strona 136 - 130 IQS-2600B

SCPI Command ReferenceTunable Laser Source 87Product-Specific Commands—DescriptionExample(s) SOUR:WAV?Notes This function cannot be performed while th

Strona 137 - Tunable Laser Source 131

SCPI Command Reference88 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:MODEDescription This command is used to toggle between

Strona 138

SCPI Command ReferenceTunable Laser Source 89Product-Specific Commands—Description:SOURce[1..n]:WAVelength:MODE?Description This query returns the cur

Strona 139 - Tunable Laser Source 133

SCPI Command Reference90 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:MODEDescription This command allows you to selec

Strona 140 - ₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩

SCPI Command ReferenceTunable Laser Source 91Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:MODE?Description This query returns t

Strona 141 - MARKING REQUIREMENTS

SCPI Command Reference92 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:CYCLeDescription This command specifies the numb

Strona 142

SCPI Command ReferenceTunable Laser Source 93Product-Specific Commands—DescriptionExample(s) SOUR:WAV:SWE:REP NCONSOUR:WAV:SWE:CYCL 32Notes This funct

Komentarze do niniejszej Instrukcji

Brak uwag