Signal Test
230 FTB-635
TX/RX Tone Test
The page displays the following parameters:
Send Tone allows you to select the Wideband Frequency or Voice
Frequency for the Send tone.
Level allows you to set the send tone level.
Level Step allows you to set the send tone level step.
Frequency allows you to set the send tone frequency to be used.
Frequency Step allows you to set the send tone frequency step.
Termination Resistance displays the termination resistance.
Note: The Level or Frequency values can be increased or decreased by selecting
the Level or Frequency and pressing up or down arrows on the FTB-1
keypad.