Exfo FTB-635 Wideband Copper and DSL Test Module Instrukcja Użytkownika Strona 155

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 154
Multimeter Tests
Copper and xDSL Tests 147
Resistance Test
Setting Threshold Values
The Test Threshold page allows you to set the Threshold Resistance for
each pair.
To set the Threshold values:
1. From the Copper main menu Test Groups, select Multimeter test
.
2. From the Tests menu, select Resistance test.
3. Tap Continuous tab to set the Threshold values.
4. Tap Edit Thresholds button to open the Test Thresholds page.
5. Set the Threshold values as required.
6. Tap Close to confirm and exit the page.
The page allows you to set the following parameters:
Threshold is the threshold limit for each pair: Maximum, Minimum, or
None.
Threshold Resistance sets the threshold value.
Przeglądanie stron 154