Configuring and Starting a Test
Ethernet Tester Analyzer 51
RFC 2544 Test Parameters Setup
Resolution, %: throughput analysis resolution value. Possible values:
10 ( F1), 1 (F2 ), 0.1 (F3 ), 0.01 (F4 ). Lesser resolution value is, the
bigger throughput analysis accuracy is.
Threshold, %: throughput analysis threshold of loss value in percent of
current load. Possible values: 0 - 10 %. Trial is successful if loss doesn’t
exceed the threshold. This feature allows to determine through-put of
channel with invariable loss. As per rfc2544 trial is successful if loss is 0.