Strona 1 - FPM-300/FLS-300/FOT-300

User GuidePower Meter/Light Source/OpticalLoss Test SetFPM-300/FLS-300/FOT-300

Strona 2

Safety Information 5Equipment RatingsTemperature Operation Storage-10 °C to 50 °C (14 °F to 122 °F)-40 °C to 70 °C (-40 °F to 158 °F)Relative humidi

Strona 3 - Contents

FPM-300/FLS-300/FOT-300 63 Getting StartedTurning the Unit On and OffWhen you turn off the FPM-300 or the FOT-300, it saves the current wavelength, un

Strona 4 - Certification Information

Getting Started 7Activating Automatic Shutdown (Auto-Off)When auto-off is activated, the unit will turn off after 10 minutes of idle time.Auto-off is

Strona 5 - DECLARATION OF CONFORMITY

FPM-300/FLS-300/FOT-300 8Cleaning and Connecting Optical FibersTo connect the fiber-optic cable to the port:1. Inspect the fiber using a fiber inspect

Strona 6 - 1 Introducing the

Measuring Power or Loss (FPM-300 and FOT-300) 94 Measuring Power or Loss (FPM-300 and FOT-300)Nulling Electrical OffsetsTemperature and humidity varia

Strona 7 - FOT-300 FLS-300FPM-300

FPM-300/FLS-300/FOT-300 10 Defining a List of Favorite WavelengthsYou must put the wavelengths you want to use on a list of favorite wavelengths (the

Strona 8

Measuring Power or Loss (FPM-300 and FOT-300) 11Referencing Your Power Meter to a SourceIn reference mode, your unit displays the loss created by the

Strona 9 - 2 Safety Information

FPM-300/FLS-300/FOT-300 12To reference the power meter to a source manually:1. Using the proper adapter, connect a light source (such as FLS-300 or FO

Strona 10 - Safety Information 5

Measuring Power or Loss (FPM-300 and FOT-300) 13Measuring Power or LossMeasuring absolute power or link loss is done the same way, except for the refe

Strona 11 - 3 Getting Started

FPM-300/FLS-300/FOT-300 146. Match the source and power meter wavelengths: If the source emits an auto-wavelength signal (see Automatically Detecting

Strona 12 - Getting Started 7

iiCopyright © 2003–2011 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in a

Strona 13 - IMPORTANT

Measuring Power or Loss (FPM-300 and FOT-300) 15Automatically Detecting WavelengthCompatible sources (such as FOT-300 and FLS-300) can transmit their

Strona 14 - (power meter)

FPM-300/FLS-300/FOT-300 165 Using a Light Source (FLS-300 and FOT-300)The FLS-300 may contain up to three sources (one-port models) or up to four sour

Strona 15 - FPM-300/FLS-300/FOT-300 10

Using a Light Source (FLS-300 and FOT-300) 17Sending Source Power Value with SignalYour source can transmit a user-defined power value to compatible p

Strona 16

FPM-300/FLS-300/FOT-300 18To send the source power value:1. Activate the source.2. Hold down a few seconds. The unit switches to PREF mode and displ

Strona 17

Maintenance 196 MaintenanceThis product contains no user-serviceable parts. However, it contains sensitive electronic and optical components, and shou

Strona 18 - Measuring Power or Loss

FPM-300/FLS-300/FOT-300 20Cleaning EUI ConnectorsRegular cleaning of EUI connectors will help maintain optimum performance. There is no need to disass

Strona 19

Maintenance 215. Repeat steps 3 to 4 with a dry cleaning tip.Note: Make sure you don’t touch the soft end of the cleaning tip.6. Clean the ferrule in

Strona 20

FPM-300/FLS-300/FOT-300 22Cleaning Fixed ConnectorsRegular cleaning of connectors will help maintain optimum performance. Do not try to disassemble th

Strona 21 - 5 Using a Light Source

Maintenance 236. Moisten a cleaning tip (2.5 mm tip) with only one drop of isopropyl alcohol.7. Slowly insert the cleaning tip into the connector unti

Strona 22

FPM-300/FLS-300/FOT-300 24Cleaning Detector PortsRegular cleaning of detectors will help maintain measurement accuracy.To clean detector ports:1. Remo

Strona 23 - FPM-300/FLS-300/FOT-300 18

FPM-300/FLS-300/FOT-300 iiiContentsCertification Information ... v1 In

Strona 24 - 6 Maintenance

Maintenance 25Recalibrating the UnitManufacturing and service center calibrations are based on the ISO/IEC 17025 Standard, which states that calibrati

Strona 25

FPM-300/FLS-300/FOT-300 267 TroubleshootingSolving Common ProblemsError Codes and Descriptions ER: error code displayed until you press a key. WR: w

Strona 26

Troubleshooting 27Contacting the Technical Support GroupTo obtain after-sales service or technical support for this product, contact EXFO at one of th

Strona 27

FPM-300/FLS-300/FOT-300 288 WarrantyGeneral InformationEXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship for a peri

Strona 28

Warranty 29ExclusionsEXFO reserves the right to make changes in the design or construction of any of its products at any time without incurring obliga

Strona 29

FPM-300/FLS-300/FOT-300 30Service and RepairsEXFO commits to providing product service and repair for five years following the date of purchase.To sen

Strona 30

Warranty 31EXFO Service Centers WorldwideIf your product requires servicing, contact your nearest authorized service center.EXFO Headquarters Service

Strona 31 - 7 Troubleshooting

FPM-300/FLS-300/FOT-300 32A Technical SpecificationsIMPORTANTThe following technical specifications can change without notice. The information present

Strona 32 - (source)

Technical Specifications 33Model FOT-302 FOT-302XPower meter port b Ge GeXPower range (dBm) c 10 to —60 26 to —50Range displayed (dBm) Down to

Strona 33 - 8 Warranty

NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT

Strona 34

ivCertification InformationFederal Communications Commission (FCC) and Industry Canada InformationElectronic test and measurement equipment is exempt

Strona 35 - Service and Repairs

www.EXFO.com · [email protected]/N: 1062089CORPORATEHEADQUARTERS400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-21

Strona 36 - Warranty 31

FPM-300/FLS-300/FOT-300 vPage 1 of 1 DECLARATION OF CONFORMITY Application of Council Directive(s): 2006/95/EC – The Low Voltage Directive 2004/10

Strona 37 - A Technical Specifications

Introducing the FPM-300/FLS-300/FOT-300 11 Introducing the FPM-300/FLS-300/FOT-300This user guide covers the following products (unless otherwise spec

Strona 38 - STANDARD ACCESSORIES

FPM-300/FLS-300/FOT-300 2LCD displayDC connectorKeypad(FOT-300 shown)StandShoulderstrap eyeletPower meterdetector portLight sourceportsFOT-300 FLS-300

Strona 39 - ₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩

Introducing the FPM-300/FLS-300/FOT-300 3Power SourcesThe units operate with the following power sources: AC adapter (connected to standard power out

Strona 40

FPM-300/FLS-300/FOT-300 42 Safety InformationElectrical Safety InformationLaser Safety Information (FLS-300 and FOT-300)Your instrument is a Class 1 l