Test Functions
466 FTB/IQS-88000 Series
OH - SONET/SDH
STS/AU/TU-3
J1: Trace. Available when the Trace format is set to 1 Byte (Refer to
Traces (SONET/SDH) on page 246).
SONET: The J1 Trace byte provides a 16 or 64 byte fixed string to verify
connection between path transmitting equipment and path receiving
equipment.
SDH: The higher-order (AU)/low-order (TU) VC-N path trace byte
provides a 64 byte fixed string to verify connection between path
transmitting equipment and path receiving equipment.
B3: BIP-8. The BIP-8 (Bit-Interleaved Parity) byte provides path error
monitoring. The byte is calculated by performing a even-parity check
over all bits of the previous SPE.
C2: Signal Label. Entering a C2 byte value will automatically update the
Path Signal Label (C2) selection and vice versa. Refer to
STS/AU Path (C2) on page 146 for more information.
C2
(Hex.)
Description
SONET SDH
00
a
Unequipped UNEQ or supervisory-UNEQ
01 Equipped - Non-Specific RES (Equipped - Non-Specific)
02 Floating VT Mode (Default) TUG Structure
03 Locked VT Mode Locked TU-n
04 Async Mapping for DS3 Async Mapping of 34M/45M in C-3
05 Mapping under development Experimental Mapping
12 Async Mapping for 140M (DS4NA) Async Mapping of 140M in C-4
13 Mapping for ATM ATM Mapping
14 Mapping for DQDB MAN DQDB
15 Async Mapping for FDDI FDDI [3]-[11] Mapping
16 Mapping of HDLC over SONET Mapping of HDLC/PPP
17 SDL with self-sync scrambler RES (SDL self-synch scrambler)
18 Mapping of HDLC/LAPS Mapping of HDLC/LAPS
19 SDL with a set-reset scrambler RES (SDL set-reset scrambler)
1A 10 Gbit/s Ethernet (IEEE 802.3) 10 Gbit/s Ethernet (IEEE 802.3)