Test Results
Power Blazer 279
Alarms/Errors
Interface
Alarms
LOS
1
(Loss Of Signal)
RX: Absence of an input signal or an all-zeros pattern is received.
LOC Lane
2
(Loss Of Clock Lane) is available for parallel interface
RX: The module is unable to lock on the Physical/CAUI/XLAUI link
interface.
Int. RX Fault (Interlink RX Fault) is available with serial CFP
RX: Fault detected at the interlink point between the FTB/IQS-88000
Series and the CFP, an unexpected signal is coming out from the CFP.
Frequency
2
RX: The received signal frequency meets the standard specifications
(green) or not (red).
For Ethernet 10/100/1000M Electrical, 100M Optical, 1GE Optical,
10GE LAN/WAN, or Fibre Channel 1X/2X/4X/8X/10X/16X interface/rate,
the frequency range is ± 100 ppm.
For parallel interfaces:
1. Available for each Optical Lane for parallel interface.
2. Available for each Physical Lane for parallel interface.
Rate Optic Type Frequency
OTU3 4x10G 10.7546 Gbit/s ± 20 ppm
OTU3e1 4x10G 11.1427 Gbit/s ± 20 ppm
OTU3e2 4x10G 11.1458 Gbit/s ± 20 ppm
OTU4 10x10G, 4 x 25G 11.181 Gbit/s ± 20 ppm