Ethernet and Fibre Channel Application 411
ASpecifications
Ethernet Optical Interfaces
For FTB-8510B:
IMPORTANT
The following technical specifications can change without notice.
The information presented in this section is provided as a reference
only. To obtain this product’s most recent technical specifications,
visit the EXFO Web site at www.exfo.com.
Bidirectional Optical Interfaces 1000Base-BX10-U 1000Base-BX10-D
Wavelength (nm) TX: 1310
RX: 1490
TX: 1490
RX: 1310
Tx level (dBm) -9 to -3 -9 to -3
Rx level sensitivity (dBm) -20 -20
Maximum reach 10 Km 10 Km
Transmission bit rate (Gbps) 1.25 1.25
Reception bit rate (Gbps) 1.25 1.25
Tx operational wavelength range (nm) 1260 to 1360 1480 to 1500
Measurement accuracy:
Frequency (ppm)
Optical power (dB)
±15
±2
±15
±2
Maximum Rx before damage (dBm) ±6 ±6
Optical interfaces Two ports at 100M and GigE
Available wavelengths (nm) 850, 1310 and 1550
100Base-FX 100Base-LX 1000Base-SX 1000Base-LX 1000Base-ZX
Wavelength (nm) 1310 1310 850 1310 1550
Tx level (dBm) —20 to —15 —15 to —8 —9 to —3 —9.5 to —3 0 to +5
Rx level sensitivity (dBm) —31 —28 to —8 —20 —22 —22
Maximum reach 2 km 15 km 550 m 10 km 80 km
Transmission bit rate (Gbit/s) 0.125 0.125 1.25 1.25 1.25
Reception bit rate (Gbit/s) 0.125 0.125 1.25 1.25 1.25
Tx operational wavelength range (nm) 1280 to 1380 1261 to 1360 830 to 860 1270 to 1360 1540 to 1570
Measurement accuracy
Frequency (ppm) ±4.6 ±4.6 ±4.6 ±4.6 ±4.6
Optical power (dB) ±2 ±2 ±2 ±2 ±2
Maximum Rx before damage (dBm) +3 +3 +6 +6 +6
Jitter compliance ANSI X3.166 IEEE 802.3 IEEE 802.3 IEEE 802.3
Ethernet classification ANSI X3.166 IEEE 802.3 IEEE 802.3 IEEE 802.3
Laser type LED FP VCSEL FP DFB
Eye safety CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1
Connector LC LC LC LC LC
Transceiver type SFP SFP SFP SFP SFP
OPTICAL INTERFACES