Test Setup - Test Configurator, Timer, and System
172 FTB-700G/800 Series
RFC 2544 - Subtests
RFC 2544 - Subtests
From the Test menu, tap Setup, Test Configurator, tap on the RFC 2544
block. and on the Subtests tab.
Allows the configuration of each enabled subtest.
Throughput
The objective of this test is to find the throughput of the device under test
for which there is no frame loss. Starting at the specified maximum rate
(Max. Rate), the rate converges towards the highest throughput without
frame loss. The search is done with a halving/doubling method until a final
value is reached. The throughput measurement is validated the number of
times specified (Validations) for the predefined duration (Trial Duration).
The Accuracy setting specifies how precise the result must be. The test is
performed for each defined frame size.