Testing Fibers in Advanced Mode
78 OTDR
Setting Pass/Fail Thresholds
Setting Pass/Fail Thresholds
You can activate and set Pass/Fail threshold parameters for your tests.
You can set thresholds for splice loss, connector loss, reflectance, fiber
section attenuation, span loss, span length, and span ORL. You can apply
the same pass/fail thresholds to all test wavelengths or apply them
separately to each one.
You can set different pass/fail thresholds for each available test
wavelength. These pass/fail thresholds will be applied to the analysis
results of all newly acquired traces with the corresponding wavelength.