Exfo FTB-7000 OTDR for FTB-200 v2 Instrukcja Użytkownika Strona 158

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 157
Analyzing Traces and Events
144 FTB-7000 Series
Deleting Events
Deleting Events
Note: This function is available in Advanced mode only.
Almost any event can be deleted from the events table, except:
³ end of analysis
³ fiber section
³ launch level
³ end of fiber
³ span start
³ span end
Note: The “End-of-fiber” event indicates the span end that was set for the first
analysis of the trace, not the span end assigned to another event or
distance from the span end in the Analysis tab.
IMPORTANT
The only way to “recover” deleted items is to reanalyze the trace, as
you would for a new trace. For more information, see Analyzing or
Reanalyzing a Trace on page 151.
Przeglądanie stron 157
1 2 ... 153 154 155 156 157 158 159 160 161 162 163 ... 338 339

Komentarze do niniejszej Instrukcji

Brak uwag