Analyzing Traces with the Bidirectional Analysis Application (Optional)
OTDR 213
Reanalyzing Traces and Regenerating the Bidirectional Measurement
Reanalyzing Traces and Regenerating the
Bidirectional Measurement
You can analyze the A->B and B->A traces and regenerate the
bidirectional measurement at any time. Reanalyzing a trace will:
re-create the events table if it was modified.
reset the span start to zero and the span end to end-of-fiber, unless you
have saved them (see Saving the Span-Start and Span-End Information
on page 244).
The table below shows what happens when you start the analysis,
depending on the direction that is currently selected.
Note: In the case of multiwavelength files, the analysis is performed for the
selected wavelength only.
If you prefer to focus your analysis on a specific fiber span, see Modifying
the Alignment of Unidirectional Traces on page 215.
Current direction
Bidirectional
measurement
A->B trace B->A trace
Bidirectional Regenerated Reanalyzed Reanalyzed
A->B Regenerated Reanalyzed Not modified
B->A Regenerated Not modified Reanalyzed